WALK IN COOLERS FOR BEVERAGE DISPLAY
DUE TO THE TREMENDOUS RESPONSE, OUR BLOWOUT SALE IS EXTENDED UNTIL FEBRUARY 1st 2010 (on certain door sizes, call for a quote today!)
LOOKING FOR A USED WALK-IN COOLER? WHY? YOU'VE JUST FOUND
C & D EQUIPMENT L.L.C.. WE OFFER THE HIGHEST QUALITY ALL NEW
EQUIPMENT AT PRICES THAT RIVAL USED EQUIPMENT. DON'T LET YOUR
MONEY GO TO COMMISIONS FOR OTHER COMPANIES HIGH PRESSURE
SALESMEN AND THEIR MULTIPLE LEVEL SALES ORGANIZATION.
THE OTHER GUYS PROMISE NO HARD SELL AND THEN CALL YOU
FIVE TIMES A DAY. WHAT'S UP WITH THAT?
CALL 1-800-679-9210 FOR A FREE QUOTE AND FIND OUT
WHAT THE C & D DIFFERENCE IS FOR YOURSELF.
SEEN AN AD FROM A COMPETITOR TO "BUY
DIRECT"? ASK THEIR SALESMAN WHAT PART OF
DIY WALK IN COOLERS FOR FLORAL STORAGE THE WALK IN, IF ANY, THEY ACTUALLY MANUFA-
FOR THE SMALL OR HOME FLORAL BUSINESS CTURE. THE ANSWER MAY SURPRISE YOU!
SPECIAL PRICES ON POPULAR SIZES!
 
C & D EQUIPMENTS TOP TWO CLAIMS YOU SHOULD NEVER BELIEVE
(OR HAVE A DAMNED GOOD LAUGH AT)
1. "I'M AN HONEST POLITICIAN"
2. "OUR INSULATION NEVER LOSES R-VALUE"
urethane thickness initial r-value long term r-value percentage of decrease in r-value
1" 8.57 6.00 -30%
1.5" 12.86 9.00 -30%
2" 17.14 12.10 -29%
2.5" 21.43 15.30 -29%
3" 25.71 18.50 -29%
3.5" 30.00 21.70 -28%
4" 34.00 25.00 -26%
In short, the Long Term R-Value for "Foamed in Place" urethane insulation can be as low as 6.25 per inch.
TO VERIFY THE TRUE R-VALUE OF "FOAMED IN PLACE"
URETHANE INSULATION FROM AN INDEPENDENT SOURCE.
NOT AN INTERNATIONAL URETHANE CHEMICAL MANUFACTURER!
CLICK THE LINK BELOW TO THE STATE OF COLORADO's ENERGY
CONSERVATION WEBSITE
(Look in the R-Value Table for Insulating Materials next to "Polyurethane (foamed-in-place)")
http://coloradoenergy.org/procorner/stuff/r-values.htm
DIY WALK-IN COOLERS FOR FLORAL DISPLAY NEW DEPARTMENT OF ENERGY REGULATIONS
IN PLAIN ENGLISH
FOR COOLERS AND FREEZERS UNDER 3000 SQ FT
MINIMUM R-VALUE REQUIREMENT FOR COOLERS R-25 (walls and ceiling)
MINIMUM R-VALUE REQUIREMENT FOR FREEZERS R-32 (walls and ceilng)
MINIMUM R-VALUE REQUIREMENT FOR FLOORS FOR FREEZERS IS R-28
(THE NEW CODE DOES NOT BAN ANY INSULATING MATERIAL)
DUE TO POLITICAL PRESSURE, STRUCTURAL MEMBERS OF PANELS,
i.e. WOODEN FRAMING, HAS BEEN EXEMPTED FROM THE NEW R-VALUE
REQUIREMENTS, EVEN THOUGH IT STILL SIGNIFICANTLY LOWERS THE
OVERALL R-VALUE OF THE WALK-IN COOLER OR FREEZER.
WALK IN COOLERS FOR STORAGE
SPECIAL PRICING ON POLULAR SIZES!
EITHER PERMANENT SPLIT CAPACITOR (P.S.C.) OR ELECTRONICALLY COMMUTATED (E.C.)
FAN MOTORS ARE REQUIRED ON THE REFRIGERATION SYSTEM.
ENTRANCE DOORS 45" IN WIDTH OR LESS OR 7'H OR LESS MUST BE SPRING HINGED OR
USE PLASTIC STRIP CURTAINS
COOLER GLASS DISPLAY DOORS MUST BE A MINIMUM OF EITHER
a. DOUBLE PANE GLASS WITH ONE PANE OF HEAT REFLECTIVE GLASS AND AN ARGON GAS FILL
OR
b. TRIPLE PANE GLASS WITH EITHER ONE PANE OF HEAT REFLECTIVE GLASS, OR AN ARGON GAS FILL
(IN OTHER WORDS, FOR TRIPLE PANE COOLER GLASS DOORS, THE MINIMUM D.O.E REQUIREMENT IS THAT THE TRIPLE
PANE DOOR HAVE EITHER ONE PANE OF HEAT REFLECTIVE GLASS OR AN ARGON GAS FILL, BUT DOES NOT REQUIRE BOTH)
WALK-IN FREEZERS FOR STORAGE
SPECIAL PRICING ON POPULAR SIZES AND
c. IF COOLER DOORS WITHOUT HEATED GLASS ARE NOT ENERGY EFFICIENT ENOUGH TO USE LESS THAN 3 WATTS PER SQUARE FOOT
OF GLASS, THEN AN ANTI-CONDENSATE "TECH" CONTROLLER MUST BE USED.
(ALL GEMTRON COOLER DOORS WITHOUT HEATED GLASS MEET THIS ENERGY EFFICIENCY STANDARD AND DO NOT REQUIRE A "TECH"
CONTROLLER. SOME OTHER BRANDS USE OVER TWICE THIS ENERGY LIMIT AND ALWAYS REQUIRE A "TECH" CONTROLLER!
IF COOLER DOORS ARE TO HAVE HEATED GLASS. THEY WILL BE DOUBLE PANE AND STILL REQUIRE
ONE PANE OF HEAT REFLECTIVE GLASS AND AN ARGON GAS FILL, BUT THEY ALSO MUST INCLUDE AN
AN ANTI-CONDENSATE "TECH" CONTROLLER WHICH MONITORS TEMPERATURE AND HUMIDITY AND ONLY
ACTIVATES POWER TO THE GLASS WHEN CONDITIONS REQUIRE IT
FREEZER GLASS DOORS, (ALL OF WHICH ARE HEATED), MUST BE A MINIMUM OF
TRIPLE PANE COME WITH EITHER ONE PANE OF HEAT REFLECTIVE GLASS OR AN ARGON GAS FILL AND MUST ALSO INCLUDE AN ANTI CONDENSATE
CONTROLLER.
COMMERCIAL AND INDUSTRIAL
WALK IN COOLERS & FREEZERS
Walk In Coolers For Do It Yourselfer's
UNBEATABLE VALUE / SHOP & COMPARE

Combination Units
SPECIAL PRICING ON POPULAR SIZES!
Outdoor Walk-In Coolers And Walk-In Freezers
Walk In Beer Caves & Keg Coolers
"THE COLDEST BEER IN TOWN"
SPECIALPRICING ON OUR MOST POPULAR SIZES!
TrTailer
T
REACH IN COOLERS AND REACH IN FREEZERS
END OF SUMMER BLOWOUT SALE UNTIL LABOR DAY, 2009
(on certain Gemtron door sizes, call for a quote today!)
CLICK BELOW TO LEARN MORE
MAKE IT EASY TO FIND US NEXT TIME
IN THE UPPER LEFT HAND CORNER OF INTERNET EXPLORER
CLICK ON "FAVORITES" THEN "ADD TO FAVORITES" CHANGE
THE NAME TO "WALK IN COOLER EXPERTS" AND YOU'RE DONE.
WE OFFER WALK IN COOLERS AND FREEZERS THAT MEET U.S. DEPARTMENT
OF ENERGY RQUIREMENTS THAT TOOK EFFECT JAN 01,2009 AND THE MORE
STRINGENT CALIFORNIA ENERGY COMMISION REQUIREMENTS.
To read more on Califorina Energy Commission Codes click the link below:
http://www.energy.ca.gov/2006publications/CEC-400-2006-002/CEC-400-2006-002.PDF
WALK-IN COOLERS AND FREEZERS AND BEER CAVES: CONSUMER INFORMATION:
At its most basic, a walk in cooler or walk in freezer, or beer cave is nothing more than an insulated compartment
with the appropriate refrigeration system to maintain the desired internal temperature and/or humidity
level.
We will be discussing walk-in coolers and freezers and beer caves which are modular, meaning they are constructed on
site from insulated panels with a metal skin, and are joined together by "cam-locks" which are pre-built
into the sides of the panels, allowing them to be joined together from inside of the cooler or freezer with
nothing more than an Allen wrench, which is usually supplied with the panels.
PANEL CONSTRUCTION TYPES:
There are four main types of panel construction in use today for walk in coolers and walk in freezers.
1. Foamed in place: (Frameless) The two metal skins are placed in a mold, and the urethane compound is blown, or "foamed"
into the mold with a blowing agent, either R-134A or Pentane. The only thing attaching the metal skin that is Laminated to the insulating
material, is the "gluing" or adhesive properties of the blown in urethane compound as it sticks to the inside of the laminated metal skins
as it dries.
In this tye of construction, the panel is not put in a press as with "Press Set" panel construction, (See 4.), so foaming rate,
blowing agent ratio, and prepartion of metal skins is very critical to prevent air pockets and delamination.
Gaps, cracks, and channels can be incorporated into the panel insulation without carefull attention in the manufacturing process to
quality control. Since it is not placed in a press, and their is no physical attachement of the metal skin as in a framed panel,
delamination of the metal skin from the insulating material is more likely to be a problem with this type of panel construction.
2. Foamed in place: (Wood frame construction) In this type of panel there is a wooden frame constructed of inexpensive
pine or fir "2x4's".
In this type of panel you have a wooden frame with insulating material in the center of the wooden frame.
The metal skin is typically crimped over the edge of the wooden frame and attached to the wood by staples.
The tongue and groove on the edges of the panels are formed from the same wooden frame, so that you have
wood mating to wood when the panels are put together.
In Foamed in Place panel construction, the metal skin is bonded (Laminated) to the insulation through chemical adhesion, (glue),
in a Foamed in Place panel the glue is the stickiness of the not yet hardened urethane material as it foamed either into a mold with no frame
("foamed in place" frameless), or foamed into the wooden or High Density Rail frame of the panel.
Since there is only very slight internal pressure between the expanded urethane material that has been blown in and the
metal panel skin, metal preparation is of utmost importance to prevent de-lamination of the metal skin from the insulating material on a
Foamed in Place panel.
A "2x4" is actually nominally 1 1/2" x 3 1/2", so when you see a panel that is 3.5" thick, it is usually a wooden framed panel.
Wooden framed panels are inexpensive to manufacture and are a popular panel with manufacturers for this reason.
The only advantage of wood frame construction for the owner is good structural strength provided by the wooden
frame portion of the panel. This could be important for large ceiling span lengths in outdoor conditions subject to a
heavy snow load for instance.
Their are several important problems with wood frame construction:
a. Wood has a very poor R-value, (ONLY A LITTLE OVER R-1 PER INCH), so the panels overall R-Value is greatly
reduced by the wooden frame, regardless of what type of insulation is used in the center of the panel.
b. Wood, when subject to constant moisture as the result of condensation, as you have in a walk in cooler or freezer
application will eventually rot.
c. Wood under these conditions also commonly develops black mold.
d. In high humidity environments such as near restauarant kitchens, profuse sweating at the low R-Value wooden frame
is often seen, sometimesd even to the point of watter puddling on the floor at the base of the panels.
3. High Density Rail: (Not to be confused with "Foam Rail") The highest performance possible with a
"foamed in Place" panel.
This type of panel has advantages of both the soft nose and wood framed panels. Its main drawback is its price, which is higher than wood frame or soft nose panel construction.
In this type of panel, the frame is composed of high density urethane or polystyrene "boards". The density of urethane
used in the insulating portion of a urethane insulated panel is about 2.2 lbs per board foot. The high density frame portion
of a high density rail panel is about 8 lbs per board foot. The higher density required for the rail portion of the panel
sacrifices some of the panels R-Value, since with urethane or polystyrene, the higher the density, the lower R-Value.
In this type of panel you have the high structural strength of a wood framed panel, without sacrificing the insulating value
of the panel as with wood frame construction.
In this type of panel, you have both a chemical, (adhesive), bond between the metal skin and insulating material, and also a
physical structural attachment between the metal skin of the panel and the panels insulating material.
For walk-ins requiring a floor subject to heavy weight loads, such as pallets, this type of panel construction is superior.
Another advantage is that High Density Rail panels are not subject to rot as wood framed panels are.
4. Press Set (Insulating Edge) construction: An excellent comination of performance and price. In this type of panel there is no frame per se.
The metal skin is formed around the edges of the insulating material, with a thermal break between the two halves to maximize it's insulating ability.
This type of panels core is composed of solid sheets of insulating material, (either expanded polystyrene of varying densities,
urethane, or extruded polystyrene, so air pockets, gaps, channels and cracks cannot occur as with "either type of "foamed in place"
urethane panel construction.
In both Press Set and Foamed in Place panel construction, the metal skin is bonded to the insulation through chemical adhesion, (glue),
in a Foamed in Place panel the glue is the stickiness of the not yet hardened urethane material as it foamed either into a mold with no frame
("foamed in place" frame less), or foamed into the wooden or High Density Rail frame of the panel. Since there is only very slight internal pressure
between the expanded urethane material that has been blown in and the metal panel skin, metal preparation is of utmost importance to prevent
de-lamination of the metal skin on a Foamed in Place panel.
In Press Set panel construction, unlike "foamed in place" the panel skin to insulation bond is a three step process, with the chemical adhesiveis being
applied between the metal skin and insulating material and then placed in a press for up to 24 hours to ensure a positive bond between the metal
skins and the insulating material.
In this type of panel, the tongue and groove is formed from the insulating material itself, so that you have insulating
material mating to more insulating material. This type of panel gives the best insulating value.
It has a lower structural rigidity than a wood framed panel, which could be important on wide
roof spans when subject to snow loads in outdoor applications.
PANEL SKINS:
1. Stainless Steel: Very corrosion resistant but also very expensive. A major drawback is that it easily shows smudges
from hands and fingers, and is not easy to keep clean.
(Never clean Stainless Steel with "bleach" or solutions containing "bleach", as the active ingredient in bleach, Sodium
Hypochlorite is highly corrosive to Stainless Steel.)
2. Acrylic Coated Galvalume: Second only to Stainless Steel in corrosion resistance, unlike Stainless Steel it is very
resistant to smudging and is easily kept clean because of its Acrylic coating.
The clear Acrylic coating over the Galvalume both prevents smudging and makes for easier cleaning, but also protects
the material. ALSO THERE IS NO SMUDGING OR RUB OFF WITH ACRYLIC COATED GALVALUME.
Galvalume is 12 times more corrosion resistant than G 60 grade galvanized steel and 6 times more corrosion resistant
than G 90 grade galvanized steel.
Its main drawback is that it is more expensive than G90 or G60 grade galvanized steel.
Same as Galvalume below except for its Acrylic coating.
3. Galvalume and Galfan: Both are composed of steel that has been plated with highly corrosion resistant aluminum
and zinc compounds.
This combination gives the material both rigidity and dent resistance as well as excellent corrosion resistance.
It has a flat Silver appearance and is usually embossed.
4. Aluminum: Very resistant to corrosion except for saltwater environments or use in dairy applications where the
Aluminum will come in frequent contact with milk or other dairy products containing lactic acid. It is somewhat more prone
to denting than Galvanized Steel or Galvalume.
5. G 90 Galvanized: Probably the most commonly used skin for walk-in coolers. While not as corrosion resistant
as Galvalume or Stainless Steel, it is less expensive.
The "90" in G90 describes the quantity by weight per square foot of corrosion resisting zinc coating.
With Galvanized steel, the greater the amount of zinc the greater the protection against panel corrosion.
Two commonly used Galvanized steels are designated as G90 and G60. These designations relate to the total amount of
zinc compounds per square foot of area.
G90 contains 0.9 ounces of zinc for every one square foot of panel while G60 contains only 0.6 ounces of zinc.
The important fact to consider is that G90 contains 50% more protective zinc than G60 substrate.
This difference will have a direct correlation to panel longevity and long-term aesthetics of your cooler or freezer.
6. G 60 Galvanized: LOWEST CORROSION RESISTANCE OF ANY METAL SKIN! PLEASE READ MORE NEXT TO G 90
ABOVE
TYPES OF INSULATING MATERIALS:
MOST INSULATING MATERIALS R-VALUES ARE COMMONLY REFERRED TO
AT TEST TEMPERATURES USED IN THE HOME CONSTRUCTION INDUSTRY
FOR INSULATING INTERIOR WALLS OF HOMES.
THIS FIGURE IS MIS-LEADING FOR A WALK-IN COOLER OR WALK IN FREEZER
APPLICATION, BECAUSE OF COURSE WALK IN COOLER WALLS ARE USUALLY
AT 35F, AND WALKIN FREEZER WALLS ARE AT 0F OR LOWER, NOT 70F LIKE
THE INTERIOR OF A HOME.
BELOW IS THE THERMAL RESISTANCE PROFILE OF HIGH R XPS INSULATION AT DIFFERENT TEMPERATURES.
AT 70F / R-5 PER INCH (4 INCH PANEL R-20)
AT 55F / R-7.2 PER INCH (4 INCH PANEL R-28.8)
AT 35F / R-7.7 PER INCH (4 INCH PANEL R-30.8)
AT 25F / R-8.1 PER INCH (4 INCH PANEL R-32.4)
UNLIKE URETHANE, HIGH R-VALUE XPS INSULATION PERFORMS BETTER AT TEMPERATURES USED IN THE REAL WORLD
FOR WALK-IN COOLER AND WALK IN FREEZER APPLICATIONS
Expanded Polystyrene (EPS): This well proven insulating material starts as solid beads that are expanded into
conjoined foam beads through the use of heat in the form of steam.
This material comes in two densities, normal density (about 1lb per square foot), which is suitable for cooler applications,
and high density (about 2.25lbs per square foot), which is needed when being used for a walkin freezer application.
The millions of tiny cells which result are filled with air, which give polystyrene its low thermal conductivity.
It has a very stable R-Value and a very good resistance to moisture penetration as can be seen through its widespread
use as a flotation material. Unlike urethane insulation, it loses very little of its R-Value over time.
It is an insulating material that will pay dividends in energy savings for the life of the walk-in cooler or freezer.
Urethane / Polyurethane: This material is formed from the reaction of two chemicals and is usually foamed through
the use of a lighter than air blowing agent such as Pentane or R134A.
Care must be taken by the manufacturer in the panel fill process with urethane / polyurethane insulated panels to avoid
air pockets in the panel as the mixture is foamed in place.
Air pockets cannot occur with expanded polystyrene or extruded polystyrene insulation.
Urethane achieves its high initial R-Value because of the lighter than air blowing agent that is trapped in the millions of tiny cells
that compose the material as the foam sets or "dries".
While its initial R-Value is fairly high, its R-Value is not as stable as polystyrene. Meaning that it can lose much of its
high initial R-Value due to outgassing of the cells that compose the material.
Its drawback is that because the gas in the cells is lighter than air, it is under constant pressure from the surrounding
atmosphere to escape the cells, much as a balloon filled with Helium would.
As the lighter than air gas escapes it is replaced by air and moisture, the enemy of any insulation. As a result,
the high initial R-Value of the urethane insulation drops, thereby substantially reducing its R-value over time.
This process, and its effect on urethanes R-Value is know as "Thermal Drift". This effect is reduced because of the
metal skin but still occurs.
On the other hand, extreme R-Value degradation in polyurethane / urethane which was seen at one time in "unskinned"
applications subject to exposure to direct sunlight, such as sheets of raw urethane without a vapor / radiant barrier.
This problem has been resolved through the use of vapor / radiant barriers, as now used in the roofing industry, or
metal skins as is used with walk-in cooler panels.
It has a relatively low resistance to moisture penetration.
When urethane is manufactured, the cell gas is mostly blowing agent, (now Pentane or R-134A), which have a low thermal
conductivity.
Over time, air and moisture will diffuse into the cells, diluting the blowing agent and degrading the thermal
value of urethane. Polystyrene on the other hand is not affected by outgassing.
Beginning in 2003 urethane manufacturers have adopted a LTTR method (Long-term Thermal Resistance).
Based upon a method for cutting very thin layers of foam, this method accelerates the air-diffusion and helps to predict
the final R-value.
As a result of this potentially dramatic lowering effect of outgassing on urethanes R-Value, most companies utilizing
urethane insulation in their panels will only refer to urethanes high initial R-Value, while not mentioning the much
lower "Aged", or "Long Term" R-Value of urethane.
In general the LTTR values now offered by the industry for urethane insulation are:
urethane thickness initial r-value long term r-value percentage of decrease in r-value
1" 8.57 6.00 -30%
1.5" 12.86 9.00 -30%
2" 17.14 12.10 -29%
2.5" 21.43 15.30 -29%
3" 25.71 18.50 -29%
3.5" 30.00 21.70 -28%
4" 34.00 25.00 -26%
In short, the Long Term R-Value for "Foamed in Place" urethane insulation can be as low as 6.25 per inch.
TO VERIFY THE R-VALUE OF "FOAMED IN PLACE"
URETHANE INSULATION FROM AN INDEPENDENT SOURCE.
LINK BELOW TO THE STATE OF COLORADO's ENERGY
CONSERVATION WEBSITE
(Look in the R-Value Table for Insulating Materials next to "Polyurethane (foamed-in-place)")
http://coloradoenergy.org/procorner/stuff/r-values.htm
High R XPS/ EXTRUDED polystyrene (HIGH R XPS EXCEEDS E.I.S.A. R- VALUE REQUIREMENTS:)
NOT TO BE CONFUSED WITH EXPANDED POLYSTYRENE AS USED IN COFFEE CUPS! OR WITH
STANDARD EXTRUDED POLYSTYRENE, AS DESCRIBED ABOVE!
High R (High R-Value) Extruded polystyrene is formulated to exceed strict Department of Energy R-Value
requirements for both coolers and freezers. It Has a very high compressive strength making it the preferred
material for both insulated building slabs and walk-in freezer and cooler floors.
High R / XPS has both high resiliency and great rigidity, these two attributes provide both great structural strength,
thereby negating the need for wood framing and wood framing's detrimental effect on whole panel R-value.
High R / XPS also provides great durabilty for flooring in high traffic area's without the "grooving" as often seeen with
urethane insulated flooring. This high resiliency and rigidity also means exceptional dent resistance
High R / XPS also has excellent moisture resistance, and very low Long Term R-Value degradation.
(Extrudeed polystyrene is not new. it was invented by former Dow research chemist
Ottis Ray Mcintire, and first patented in 1944. Since then it has undergone many improvements.
Resulting today in Dows High R-Value extruded polystyrene certified to not only meet,
but exceed new Department of Energy, Energy Independence and Security Act (E.I.S.A.)
R-Ralue requiremets)
E.I.S.A. requires a minimum R-Value for coolers of R-25, with a test temperature of 55F
Dow's High R XPS exceeds this and is rated at R-29, with a test temperature of 55F
E.I.S.A. requires a minimum R-Value for freezers of R-32, with atest temperature of 25F.
Dow's High R XPS exceeds this and is rated at R-32.4, with a test temperature of 25F
(On May 3, 2008, Ray McIntyre was posthumously inducted into the National Inventors Hall of Fame, joining nearly
400 Americans who helped elevate the human condition with inventions that transformed lives and future horizons.
Inductees to the Hall include Herbert Henry Dow (founder of The Dow Chemical Company), Henry Ford, Thomas Edison
and Alexander Graham Bell.)
SEE LINKS BELOW FOR MORE INFO ON HIGH R (HIGH DENSITY) XPS
http://www.hatzc.xpsa.com/enviro/PDFs/Fabian_Hoffee_Herrenbruck_Earthtech_2004.pdf
http://www.greenbuildingsolutions.org/s_greenbuilding/doc.asp?TRACKID=&CID=557&DID=1871&rcss=print
REFRIGERATION SYSTEM BASICS:
There are three primary components of a refrigeration system.
1. The evaporator coil: This is the part of the system that hangs from the ceiling inside of the walk in cooler or
walkin freezer, and is responsible for actually removing heat from inside of the walk in freezer or walk in cooler, in
other words, for blowing the cold air into the cooler or freezer vault.
If you have ever held an aerosol can in your hand and rapidly discharged it, you will have noticed that the can became
very cold.
The reason that the can felt cold was that the rapidly evaporating liquid propellant in the aerosol can was removing
heat from your hand as the liquid refrigerant in the can evaporated from a liquid state into a gaseous state, thereby
making it feel cold.
The same evaporative cooling effect can be experienced as Alcohol evaporates from your skin. As the Alcohol evaporates
from your skin it removes heat, making your skin cold.
This is exactly what happens in an Evaporator Coil. The liquid refrigerant from the compressor flows from the
compressor through a flow metering device called an expansion valve into the Evaporator Coil, where it then rapidly
expands, or "evaporates".
This occurs in a series of finned metal coils that a fan or fans are blowing over. What is actually occurring is that large
amounts of heat are being removed from the air inside the cooler or freezer as the air, forced by the fans, flows over
the Evaporator Coil fins.
What we feel is the cold air that is produced as it blows into the cooler or freezer.
The refrigerant, now a gas, flows back to the Compressor.
2. The compressor: This is the Heart of the refrigeration system. Its primary purpose is to compress the refrigerant
coming from the Evaporator Coil as a gas, back into a liquid so that heat can be removed, and the refrigeration cycle
can continue.
(The two most popular types of compressors in use today are either Hermetic or Scroll. These will be discussed later.)
As the compressor recompresses the gas refrigerant coming from the Evaporator Coil, large amounts of heat are
released.
This heated gas refrigerant now goes to the Condenser to be dissipated.
3. The condenser: This is similar in function to a cars radiator. It is a series of large finned metal coils that looks
much like a cars radiator. The very hot gas refrigerant comes from the compressor into the Condenser coils as a
powerful fan or fans blows large amounts of air over the Condenser coils. The heat produced as a result of the
refrigerants compression by the compressor is dissipated as a result of the removal of heat, and the pressure in
the system.
The gas now becomes a liquid again, allowing the refrigeration cycle described above to continue.
TYPES OF REFRIGERATION SYSTEMS:
There are two major types of refrigeration systems. One is referred to as either a split, or remote system.
Either term describes the same system. In this approach, the evaporator coil is one separate unit, and the condenser
and compressor are combined as another separate unit.
The split / remote system is usually required for beverage display coolers and larger walk-in coolers and walk-in freezers
because of the size limitations of self contained refrigeration systems.
Split / Remote Refrigeration Systems: This type of system includes both indoor and outdoor remote systems.
The types we will discuss are field piped and charged. (There is another type of split system which will not be discussed
here, which involves lines which are pre-charged with refrigerant. These systems are seldom used because they still
require a Licensed refrigeration technician for installation, are more expensive, and do not provide the flexibility of a field
piped and charged system.)
This type of system is usually needed for beverage display coolers and walk in coolers larger than 8' x14', and walk in
freezers larger than 8' x 10' due to cooling capacity limitations on this type of system.
Indoor Remote: This type of system is the most inexpensive, but seldom make sense for the user. As a result of its
low price, this type of system is highly used by sellers of walk-in coolers and walk in freezers as the low price bait to entice
the customer to call.
In this type of system the condenser / compressor comes as one unit, but can only be installed indoors in an area not
subject to low temperature conditions.
In this, and all remote / split systems, the evaporator coil and condenser / compressor are separate units requiring
the expense of installation.
In this type of system the user still incurs the expense of installation of a remote system. Which will require a Licensed
refrigeration technician to run copper tubing between the evaporator coil and condenser / compressor, an electrician
to run control wiring between the condenser / compressor unit and evaporator coil, run drain lines from the evaporator
coil to drain away the water from the ice melted off the evaporator coil during the defrost cycle, and charge the
refrigeration system with refrigerant.
The only time this system would make sense, is if the condenser / compressor unit were to be located far away from the
walk in cooler or walk in freezer, such as in a basement. Since this scenario is seldom the case, and the user usually
intends to mount the compressor on top of the walk in cooler or walk in freezer, the better choice would be a self
contained refrigeration system.
Outdoor Remote:
Same as indoor remote, with the exceptions that the compressor / condenser unit is designed to be installed outdoors in
either rain or snow, and has special controls so that it can properly function in low temperature conditions.
SELF CONTAINED REFRIGERATION SYSTEMS: In this type of system all of the components of a refrigeration
system are contained in one package and is pre-charged with refrigerant. Because of refrigeration size limitations, this
type of system is usually only available for relatively small walk in coolers and walk in freezers.
This type of system includes Penthouse units which are mounted on top of the walk in cooler or freezer, and wall mount
units which are mounted on the wall of the cooler or freezer. (A Seldom used system also available is like the wall mount,
but is rolled up to the opening on the wall of the cooler or freezer.)
Penthouse Refrigeration (Also Referred to as "Drop In"): This is the most popular type of
self contained refrigeration system.
The Penthouse unit mounts on top of the walk in cooler or walk in freezer into a pre cut opening on one of the ceiling
panels.
It mounts flush with the inside of the ceiling so that none of it hangs down into the cooler or freezer, maximizing usable
interior space.
The unit is pre-charge with refrigerant, should usually come with an attached power cord, has a factory set defrost timer,
and is therefore "plug and play". Requiring no plumbing, control wiring, or refrigeration technician for installation.
Thereby greatly reducing total cost for your walk -in cooler or freezer.
Wall Mount Units: same as Penthouse units above, except that they mount on one of the walls as opposed to the
ceiling.
Roll Up Units: Basically a wall mount unit mounted on casters so as to make it easier to mount in the
opening on the side of the cooler. These are systems are seldom used today.
TYPES OF COMPRESSORS:
There are two main types of compressor's in use today.
A. HERMETIC:
The most common is the hermetic compressor, this type of compressor compresses the refrigerant gas back to liquid by
use of pistons and cylinders, and as the name indicates, is hermetically sealed, this minimizes maintenance,
but does not allow the interior of the compressor to be repaired in case of break down. If there is an internal problem
the compressor cannot be repaired and therefore must be replaced. If under warranty coverage the unit is simply
replaced with another compressor. If not under warranty, a new compressor must be purchased.
B. SCROLL
A newer, more advanced and much more energy efficient type of compressor is the "Scroll Type".
These compressors use two scroll shaped elements to compress the gas in one smooth continuous motion making
them quieter and longer lasting than an old fashioned piston driven hermetic compressor, and due to the higher
compression rate and reduced leakage, and often more energy efficient as well.
For more information on the advantages of "Scroll Type" compressors from an independent source,
please visit: http://www.wisconsinpublicservice.com/farm/scroll.asp
TYPES OF EVAPORATOR COILS
There are two main types of defrost systems for evaporator coils.
A. AIR DEFROST
This is by far the most common evaporator coil systems in walk in coolers where a temperature of 35 degrees fahrenheit
or higher is desired.
As the name implies, the ice that forms on the evaporator coils cooling fins during operation is melted off the coils during
defrost cycle by air from the evaporator coil fans blowing the air inside of the cooler over the coil fins and
gradually defrosting them. This system is used on most walkin cooler refrigeration systems for restaurant coolers,
beverage coolers and other medium temperature, (35 to 38F), applications.
Because defrosting is dependent on the air temperature inside of the cooler, for proper defrost to occur, the temperature
setting for the cooler should be set no lower than 35F, setting the thermostat lower than this might not allow the ice that
has built up on the evaporator coils to completely melt, eventually leading to ice build up on the coils.
Since ice is a thermal insulator, this ice build up prevents the system from removing the heat inside of the cooler as it should.
B. ELECTRIC DEFROST
For walk in beer coolers or walk in keg coolers, where very low temperatures are desirable, and in freezers, the more
expensive electric defrost coils will be needed. As the name implies, during the defrost cycle, a heating element is
employed to rapidly defrost the evaporator coils and the system can quickly complete the defrost cycle and resume operation.
This system, though more expensive, is a must for a walkin beer cooler to be able to maintain the temperature at or below
freezing, since in an air defrost system, the coils couldn't defrost by air, if the air temperature is below freezing.
If you want "the coldest beer in town" you will have to use electric defrost coils in the walk in refrigeration system for your walk
in refrigerator, walkin beer cooler or walkin keg cooler.
(If using an electric defrost system in a cooler with glass doors, you will have to use heated glass to avoid condensation on th glass)
Evaporator coil fan motors:
There are two main types of evaporator coil fan motors in use today.
Permanent Split Capacitor (P.S.C.) and Shaded Pole.
Permanent Split Capacitor (P.S.C.) fan motors are over 50% more energy efficient than "shaded pole" motors.
For comparison: The typical shaded pole motor draws 2.1 amps per fan motor. The typical P.S.C. motor only 1 amp.
Keep in mind: A typical evaporator coil has three or more fan motors. And many walk in coolers and freezers use
more than one evaporator coil, and that in an air defrost system as used in most walk in coolers, the evaporator coil
fan motors run 24 hours a day.
The only reasons that P.S.C. motors are not as commonly used as "shaded pole" fan motors in walk in coolers and freezers.
is:
1. They are more expensive than the older and less efficient "shaded pole" type fan motors.
2. There is not widespread consumer awarenes of even the option of this type of fan motor.
For more on energy saving ideas and the importance of P.S.C. motors in energy saving, please visit the link below:
http://www.wisconsingrocers.com/images/Magazine/Energy%20savings%20spring%2003.pdf#search='permanent%20split%20capacitor%20energy%20saving'
(copyright pending)
ARE YOU RUNNING YOUR WALK IN COOLER OR WALK IN FREEZER AT 70 DEGREES FAHRENHEIT? NO?
WE DIDN'T THINK YOU WOULD. THAT IS WHY WE USE DOW BRAND, HIGH R XPS.
BELOW IS THE THERMAL RESISTANCE PROFILE OF OUR HIGH R XPS INSULATION AT DIFFERENT TEMPERATURES.
AT 70F / R-5 PER INCH (4 INCH PANEL R-20)
AT 55F / R-7.2 PER INCH (4 INCH PANEL R-28.8)
AT 35F / R-7.7 PER INCH (4 INCH PANEL R-30.8)
AT 25F / R-8.1 PER INCH (4 INCH PANEL R-32.4)
UNLIKE URETHANE, OUR INSULATION PERFORMS BETTER AT TEMPERATURES USED IN THE REAL WORLD
IN WALK-IN COOLER AND WALK IN FREEZER APPLICATIONS
Whole panel R-Values for our panels is R-32.4 (at 25F)
AND EVEN BETTER AT 0F)
(Unlike our competitors 3.5" wooden framed panels where R-29 only applies to the center of the panel
AND THE FRAME IS ONLY R-5)
(due to pressure from wood frame panel manufacturers the R-value of the wood framing was exempted from E.I.S.A. energy requirements)
SPECIAL NOTICE FOR OUR CALIFORNIA CUSTOMERS.
CALIFORNIA ENERGY COMMISSION REGULATIONS PASSED IN 2006 ARE
AND MODIFIED IN 2008, ARE STILL IN EFFECT FOR 2009.
YOU CAN DOWNLOAD THE NEW LAW FROM THE LINK BELOW.
http://www.energy.ca.gov/appliances/2006regulations/index.html
(Look at pages 108 and 109 for Walk-In Refrigerators and Walk-In Freezers)
WE OFFER BOTH WALKIN COOLERS AND WALKIN FREEZERS
FOR CALIFORNIA, THAT MEET CALIFORNIA ENERGY COMMISION
REQUIREMENTS!
PROUDLY SERVING:
DALLAS, FT WORTH, SAN ANTONIO, MIAMI, CORPUS CHRISTI, BROWNSVILLE, EL PASO,
AMARILLO, LUBBOCK, SAN ANGELO, BIRMINGHAM, MIAMI, CHICAGO, LOS ANGELES,
SAN DIEGO, CAMDEN, BOSTON, OKLAHOMA CITY, STILLWELL, TULSA, PITTSBURGH,
PHILADELPHIA, MILWAUKEE, MINNEAPOLIS, ST PAUL, ARLINGTON, ATLANTA,
AUSTIN, BALTIMORE, ALBUQUERQUE, CHARLOTTE, CLEVELAND, COLORADO SPRINGS,
COLUMBUS, DENVER, DETROIT, FRESNO, HOUSTON, INDIANAPOLIS, JACKSONVILLE,
KANSAS CITY, LAS VEGAS, LONG BEACH, LOUISVILLE, JEFFERSON COUNTY,
MEMPHIS, MESA, NASHVILLE, DAVIDSON, NEW ORLEANS, NEW YORK, NEW YORK,
NY,NY, OAKLAND, OMAHA, PHILADELPHIA, PHOENIX, PORTLAND, SACRAMENTO,
ST LOUIS, SAN FRANCISCO, SAN JOSE, SEATTLE, TUSCON, VIRGINIA BEACH, STERLING HEIGHTS, MI
WASHINGTON, WICHITA, WICHITA FALLS , ALASKA, IDAHO, MONTANA, NEBRASKA, NEVADA,
NORTH DAKOTA, OREGON, SOUTH DAKOTA, UTAH, WYOMING, PLANO, ROWLETTE, MIDLOTHIAN,
ENNIS, CHESHIRE, WATERBURY, SHINODA, BURLESON, CROWLEY, ANAHEIM, SIMI VALLEY, JACKSONVILLE,
SCOTTSDALE, GILBERT, SILVER CITY, CROWLEY, CLEBURNE, WICHITA FALLS, LUBBOCK, AMARILLO,
LAREDO, DEL RIO, EAGLE PASS, MERCEDES, RANCHO CUCAMONGA, ORANGE, PORT ARTHUR, NEWARK,
CARLSBAD, BRANTFORD, BRANSON, BRANSOM, HENDERSON, CHANDLER, PEORIA, IRVINE, CHULA VISTA,
FONTANA, JOLIET, NORTH LAS VEGAS, BELVEDERE, MORRISTOWN, MILLSTONE, HILLSBOROUGH,
HILLSBORO, JAMESBURG, ENGLISHTOWN, CRASNBURY, ROCKYHILL, PRINCETON, NEWTOWN,
WEST CALDWELL, PARSIPANNY, MANSFIELD, CAMDEN, NJ, GLENDALE, SPOKANE, YONKERS, RICHMOND,
GRAND RAPIDS, DES MOINES, MOBILE, CHESAPEAKE, LUBBOCK, AUGUSTA, SHREVEPORT, MONTGOMERY,
SCOTTSDALE, FREEMONT, FORT WAYNE, MADISON, GARLAND, AKRON, GLENDALE, ROCHESTER,
PLANO, GREENSBORO, LINCOLN, HIALEAH, BATON ROUGE, NORFOLK, JERSEY CITY, BIRMINGHAM,
STOCKTON, BAKERSFIELD, SAINT PETERSBURG, RIVERSIDE, LOUISVILLE, ANCHORAGE, LEXINGTON,
NEWARK, RALEIGH, AURORA, CORPUS CHRISTI, SAINT PAUL, BUFFALO, TAMPA, TOLEDO, ANAHEIM,
CINCINNATI, PITTSBURGH, SANTA ANA, WICHITA, VIRGINIA BEACH, FRESNO, KANSAS CITY,
ALBUQUERQUE, LONG BEACH, CLEVELAND, NEW ORLEANS, TUSCON, OKLAHOMA CITY, PORTLAND,
CHARLOTTE, SEATTLE, AUSTIN, PAULSBORO, JERSEY CITY, GULFPORT, MOBILE, CHATANOOGA,
ALLENTOWN, ABILENE, QUINCY, IL, NEW YORK CITY, NYC, BRONX, BROOKLYN, QUEENS, MANHATTAN,
NY, NY. ALASKA, FLORIDA, HAWAII, IOWA, IDAHO, MAINE, MONTANA, NORTH DAKOTA, NEBRASKA,
OREGON, SOUTH DAKOTA, UTAH, DISTRICT OF COLUMBIA, WYOMING.
Delivery of our walk in coolers and walk in freezers and beer caves is available in all 50 states. Alabama, Florida, Georgia, Louisiana, Mississippi, Illinois, Indiana, Michigan, Ohio, Wisconsin, Delaware, Maryland, New Jersey, New York, Pennsylvania, West Virginia, Kentucky, North Carolina, South Carolina, Tennessee, Virginia, New England, Connecticut, Maine, New Hampshire, Rhode Island, Vermont, Idaho, Montana, Oregon, Washington, Wyoming, Alaska, California, Hawaii, Arkansas, Kansas, Missouri, Oklahoma, Texas, Arizona, Colorado, Nevada, New Mexico, Utah, Iowa, Minnesota, Nebraska, North Dakota, South Dakota
Styrofoam is the trademarked name for extruded polystyrene foam, an invention of the Dow Chemical Company that has been in production for more than 50 years.
Nearly anyone who has purchased coffee to go has heard the container being referred to as a Styrofoam cup.
However, extruded polystyrene has never been used to make disposable coffee cups. For that matter, its never been used to make portable picnic coolers either, this is another misconception. Those products are actually made from expanded polystyrene foam (EPS) NOT EXTRUDED POLYSTYRENE.
Unlike disposable cups and picnic coolers, which are notably white in color and composed of beads packed tightly together, products made from extruded polystyrene are CLOSED CELL,
and typically blue. It is used to make insulation wrap for residential homes, commercial buildings, and plumbing systems.
It is also used in road construction as an insulation layer under pavement to deter the formation of cracks and potholes that occur from seasonal freezing and thawing of the soil beneath.
Urethane could not be used for this purpose because even though it is also closed cell, urethane in constant contact with moisture loses its closed cell properties, this is why you never see
urethane used in any application where it is in constant contact with moisture.
|